ECT and Mullen are two lab tests on the same corrugated board, and they answer different questions. ECT tells you how the board behaves standing on edge in a box wall that is holding up a stack. The Mullen test tells you how hard you have to push on the flat board before something breaks through it. Most shipping boxes spend their life in stacks (on pallets, in trailers, in warehouses), which is why ECT is the rating most buyers should start with.
What does the edge crush test (ECT) measure?
ECT is the force a short strip of corrugated board can carry, standing on its edge, before it crushes. The lab method is TAPPI T 811, also called the short column test, and it covers single-, double- and triple-wall board. The freight rule that governs box certificates describes it the same way: the sample stands upright with the flutes running in the direction of the load, and the result is reported in pounds per inch of width. A 32 ECT board held 32 lb for every inch of edge before it failed.
That is exactly how a box wall is loaded at the bottom of a stack, so ECT is the input for estimating how much a box can carry. Our guide to box compression and stacking strength shows how ECT turns into a box compression estimate.
What does the Mullen (burst) test measure?
The Mullen test clamps a piece of flat board over a rubber diaphragm and pumps hydraulic pressure under it until the board ruptures. The peak pressure, in pounds per square inch, is the bursting strength. TAPPI T 810 is the method for single-wall and double-wall board in the 100 to 700 psi range; it isn’t used on triple-wall, which freight certificates rate with a puncture test instead.
A “200 lb test” box is one whose board burst at 200 psi or more. Because burst strength depends mainly on the liners, a burst-rated freight certificate also states a minimum combined weight of the facings: the liner basis weight, in pounds per 1,000 square feet.
When does ECT matter more, and when does Mullen?
Pick the rating that matches how your box is most likely to fail.
| Situation | Rating that matters most | Why |
|---|---|---|
| Boxes stacked on pallets, in trailers or in racks | ECT | The bottom boxes carry everything above them, on edge |
| Long storage, humid docks or cold rooms | ECT, with extra margin | Compression strength drops with time under load and with humidity |
| Heavy, dense or hard-edged contents (castings, fasteners, hardware) | Burst helps | The product presses on the panels and can punch through |
| Boxes handled one at a time and dropped | Both | Drops load the panels; the box still gets stacked at every stop |
| Jumbo boxes and bulk bins | ECT, plus structure | Walls carry the load above; pads, sleeves and partitions add support |
If nobody (your customer, a retailer or a freight requirement) names a rating, ask yourself what has gone wrong before. Crushed bottom boxes and leaning pallets point to ECT. Torn corners and holes punched by the product point to burst strength or a heavier liner.
How do ECT and Mullen ratings line up?
The most useful published pairing comes from the freight rule itself. NMFC Item 222 lets a box maker certify a box either by burst test (with a minimum liner weight) or by ECT, and its text names the ECT value it accepts in place of a burst value. These pairs appear in the 2025 edition of the rule (NMF 100-AY01):
| Wall | Burst test | ECT the rule accepts instead |
|---|---|---|
| Single-wall | 175 lb | 29 ECT |
| Single-wall | 200 lb | 32 ECT |
| Single-wall | 275 lb | 44 ECT |
| Double-wall | 200 lb | 42 ECT (same 80 lb and 85 inch limits in the rule’s certificate examples) |
| Double-wall | 275 lb | 48 ECT |
Treat these as freight-rule alternatives, not lab conversions. A 32 ECT board and a 200 lb test board both qualify a single-wall box for the same weight and size limit, but they are built differently and will behave differently. If you are switching an existing spec from burst to ECT, run the new box with your product before you change the whole order.
Why are ECT-rated boxes often lighter?
Compare the two certificates. A burst certificate lists a minimum combined liner weight (84 lb per 1,000 sq ft on the rule’s single-wall 200 lb example). An ECT certificate has no liner-weight line at all. The box maker only has to prove the board actually tests at the stated ECT, so it can choose the combination of liners and medium that gets there. That can mean lighter board for the same stacking performance.
The trade-off: lighter liners can mean less puncture resistance. If your product has sharp edges or concentrated weight, keep a burst requirement or a minimum liner weight in the spec.
Which rating should you put on your spec?
- If your customer, a retailer or a freight requirement names a rating, use it exactly as written.
- If the box will be stacked (most will), specify ECT and tell your supplier how it will be stacked: how high, for how long and in what humidity. Our article on how heat and humidity weaken boxes explains why that last part matters.
- If the product is heavy, dense or sharp, add a burst requirement or a minimum liner weight.
- Check the wall construction too. Going from single-wall to double-wall changes both numbers more than small grade changes do; the flute guide covers the options.
- Pack and test a real sample before committing to a production run.
The rating you choose is printed in the box maker’s certificate; how to read a box maker’s certificate walks through every line. The test methods behind both ratings are published by TAPPI.
At Ok-Go we cut samples on our own sample table within hours, so you can pack, stack and drop your real product in the real box before you approve a shipping box or a jumbo box for production.